Specifications

Carbon Dioxide Sensor Type Solid-state Infrared
CO2 Minimum Detection Limit 0.1% (0-50% or 0-100% range) or 0.01% (0-10% or 0-20% range)
Accuracy - Carbon Dioxide ± 1% of reading, or ± 0.1% CO2 (whichever is greater)
CO2 Calibration Controls Digital Keypad
CO2 Calibration Frequency Every 12 months; calibration gas recommended.
Oxygen Range 0.00 to 100%
Oxygen Sensitivity 0.01%
O2 Resolution 0.01%
Expected Lifetime (oxygen) 4-5 years
Analog Output 0-5V
Resolution 0.01%
Accuracy +/- 0.1% (from 0-20%), +/- 0.2% (from 20% to 50%), +/- 0.5% (from 50% to 100%)
Drift less than 0.4% per year
Oxygen Sensor Type Proprietary Electochemical
Response Time 20 seconds to T95
O2 Sensor Lifetime 4-5 Years
O2 Sensor Body Anodized aluminum (CO2) and ABS Resin (O2)
Sample Connection Sample Probe
Sample Method Pump
Sample Pump Internal, draws ~5cc/sec
Pump Timing 2-20 seconds, continuous, or cycling on/off, programmable
Minimum Sample Required 15cc
Sampling Assembly Probe with luer connection for tri-beveled needle, PTFE tubing
Oxygen Calibration Controls Digital Keypad Adjustment
Instrument Calibration EasyCal calibration
Exhaust port Vents to air
Power Supply 100 to 240 VAC, internationally compatibile
Battery Operation Included, internal shrink wrapped NiMH battery pack
Input Voltage 100-240V, 50-60Hz
Battery Life 12-16 hour runtime
Measures: O2, CO2 O2, CO2
Form Factor Benchtop
Size 11W x 3H x 8D in (279W x 76H x 203D mm)
Weight 3.5 lbs (1.59 kg)
Warranty 2 years, parts and labor
Standards CE, RoHS
Included Consumables 400 foam septas, 10 luer fit needles, 10 filters, spare probe tubing
Included Documentation Owner’s manual, NIST traceable calibration certificate
Origin of Goods Our goods are manufactured in the U.S.A.

Datasheets

Q30 DataSheet

What included

  • Model Q32 Analyzer
  • Power Supply for Charging
  • 400 Foam Seal Pads (P/N 9002)
  • 10 Liquid and Particulate blocking filters (P/N 9028)
  • 10 needles (P/N 9027)
  • Spare tubing for sample probe
  • USB thumb drive for downloading saved data points

Support

Email us:  [email protected]

Call us:  508-839-3940

 

———————RETURN INSTRUCTIONS————————

Returning instruments for repair or calibration is easy:

  • Ship to address below:

 

Quantek Instruments, Inc.

183 Magill Drive

Grafton, MA 01519

(508) 839-3940

ATTN:  Service

 

2)    No RMA# or other paperwork is needed.

3)    Please make sure that the analyzer is well protected.

4)  *Important* Always include a business card or contact information in the box.   We’ll typically evaluate and send estimates within 24-48 hours of receipt.  Lack of contact information may delay this process.